This glossary explains technical, regulatory, safety, performance, and commercial terminology used across the Building Products & Construction Materials sector. It helps executives, manufacturers, contractors, and advisers working in the Insulation, Roofing & Weatherization Products Practice interpret commonly encountered industry acronyms.
A B C D E F G H I K L M N O P Q R S T U V W X
| A | |
| AB | Air Barrier: A material or assembly designed to restrict uncontrolled airflow through the building enclosure, reducing heat loss, moisture transport, and drafts. |
| ABAA | Air Barrier Association of America: A trade association that develops installer accreditation, quality-assurance programs, technical guidance, and specifications for air-barrier systems. |
| ACH | Air Changes per Hour: A measure of how many times the air volume within a space is replaced in one hour, used to assess ventilation and infiltration. |
| ACH50 | Air Changes per Hour at 50 Pascals: The standardized blower-door measure of enclosure leakage at a 50-pascal pressure difference; lower values generally indicate greater airtightness. |
| ACM | Asbestos-Containing Material: Material containing regulated quantities of asbestos that may require testing, containment, or abatement before insulation, roofing, or air-sealing work proceeds. |
| AECB | Association for Environment Conscious Building: A UK organization providing standards, training, and guidance related to low-energy construction, airtightness, insulation, and building performance. |
| ANSI | American National Standards Institute: The body that coordinates voluntary consensus standards in the United States, including standards governing roofing systems, fall protection, thermal performance, and building-envelope testing. |
| APF | Assigned Protection Factor: The expected reduction in airborne contaminant exposure provided by a properly selected and fitted respirator, important during spray-foam application and hazardous-material disturbance. |
| APP | Atactic Polypropylene: A thermoplastic modifier added to asphalt to improve heat resistance, flexibility, and weathering performance in modified-bitumen roofing membranes. |
| ARMA | Asphalt Roofing Manufacturers Association: A North American trade association that publishes technical guidance and represents manufacturers of asphalt shingles and low-slope asphalt roofing products. |
| ASCE | American Society of Civil Engineers: A professional organization whose standards establish structural loads, including wind, snow, and rain loads used to design roof systems and attachments. |
| ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers: A standards organization whose requirements address energy efficiency, ventilation, moisture control, and thermal-envelope performance. |
| ASTM | ASTM International: A standards organization that publishes widely referenced test methods and product specifications for insulation, roofing membranes, shingles, coatings, vapor retarders, and air barriers. |
| ATTMA | Air Tightness Testing and Measurement Association: A UK professional body that establishes testing protocols and certification requirements for measuring building-envelope air permeability. |
| AVB | Air and Vapor Barrier: A membrane or coating that limits both airflow and water-vapor diffusion through a roof or wall assembly. |
| AVCL | Air and Vapour Control Layer: A layer used primarily in UK and European construction to control air leakage and vapor movement on the warm side of an insulated assembly. |
| B | |
| BBA | British Board of Agrément: A UK certification body that evaluates the fitness for purpose of construction products, including insulation, roofing, membranes, and weatherproofing systems. |
| BEopt | Building Energy Optimization Tool: Residential energy-modeling software used to compare retrofit packages, energy savings, and cost trade-offs for enclosure and equipment improvements. |
| BIBS | Blown-In Blanket System: A netted-cavity insulation method in which loose fibers are densely installed to form a continuous blanket around framing and obstructions. |
| BIPV | Building-Integrated Photovoltaics: Solar-generating components incorporated into roof coverings or other enclosure materials rather than mounted as separate equipment. |
| BPI | Building Performance Institute: A US standards and credentialing organization for home energy auditing, weatherization, diagnostic testing, and quality assurance. |
| BRE | Building Research Establishment: A UK research, testing, and certification organization active in building-envelope performance, fire safety, energy efficiency, and construction-product assessment. |
| BREEAM | Building Research Establishment Environmental Assessment Method: A building sustainability assessment method that can influence insulation and roofing specifications through energy, materials, health, and lifecycle-performance criteria. |
| BTU | British Thermal Unit: A unit of heat energy used in building-load calculations, fuel-consumption analysis, and estimates of weatherization savings. |
| BUR | Built-Up Roofing: A low-slope roof system assembled from multiple layers of bitumen and reinforcing felts, usually finished with aggregate, a cap sheet, or a coating. |
| C | |
| CAZ | Combustion Appliance Zone: The area containing fuel-burning equipment that is evaluated for pressure conditions, spillage, and carbon-monoxide risk during weatherization work. |
| ccSPF | Closed-Cell Spray Polyurethane Foam: A dense, rigid foam that provides insulation and air control and may also function as a vapor retarder or water-resistant material at specified thicknesses. |
| CDD | Cooling Degree Days: A climate metric representing outdoor temperatures above a base temperature, used to normalize cooling demand and model retrofit savings. |
| CE | Conformité Européenne: A marking indicating that a product covered by applicable European legislation has been assessed against required health, safety, and performance provisions. |
| CFC | Chlorofluorocarbon: An ozone-depleting chemical formerly used as a foam blowing agent; its presence can affect legacy-product management and environmental reporting. |
| CFM | Cubic Feet per Minute: A volumetric airflow unit used to quantify ventilation, exhaust, and enclosure leakage during diagnostic testing. |
| CFM50 | Cubic Feet per Minute at 50 Pascals: The airflow required to maintain a 50-pascal pressure difference during a blower-door test, providing a standardized measure of building leakage. |
| CFR | Code of Federal Regulations: The codification of US federal rules, including requirements governing weatherization programs, worker safety, hazardous materials, and environmental compliance. |
| CGSB | Canadian General Standards Board: A Canadian standards-development organization whose specifications and test methods are referenced for some insulation and building-envelope products. |
| CI | Continuous Insulation: Insulation installed continuously across structural members, except at necessary penetrations, to reduce thermal bridging through the enclosure. |
| CIGA | Cavity Insulation Guarantee Agency: A UK organization that provides guarantees for qualifying cavity-wall insulation installations and supports remediation of covered defects. |
| CIMA | Cellulose Insulation Manufacturers Association: A trade association representing cellulose insulation producers and providing technical, safety, and installation information. |
| CO | Carbon Monoxide: A colorless, odorless combustion gas that must be monitored when air sealing could alter appliance draft or building pressure relationships. |
| CRCA | Canadian Roofing Contractors Association: A national trade organization that publishes technical guidance and represents Canadian roofing contractors and industry suppliers. |
| CRRC | Cool Roof Rating Council: An independent organization that administers product ratings for roof surface solar reflectance and thermal emittance. |
| CSA | Canadian Standards Association: A standards and certification organization whose requirements apply to various insulation, roofing, air-barrier, and building-envelope products in Canada. |
| CSPE | Chlorosulfonated Polyethylene: A synthetic rubber historically used in single-ply roofing membranes because of its weathering, chemical, and ultraviolet resistance. |
| CWI | Cavity Wall Insulation: Insulation installed within the cavity of a masonry wall to reduce heat transfer, commonly as a retrofit measure in suitable buildings. |
| D | |
| DEA | Domestic Energy Assessor: A qualified UK professional who surveys homes and produces energy-performance assessments used to identify efficiency improvements. |
| DFT | Dry Film Thickness: The thickness of a coating after curing, used to verify that liquid-applied roof membranes and protective coatings meet specification and warranty requirements. |
| DOE | United States Department of Energy: The federal department responsible for national energy-efficiency programs, research, product standards, and administration of the Weatherization Assistance Program. |
| DoP | Declaration of Performance: A manufacturer-issued document reporting the performance of a construction product against its declared essential characteristics under European or UK product rules. |
| E | |
| EAD | European Assessment Document: A harmonized technical specification used to assess an innovative construction product when no suitable harmonized European standard exists. |
| ECM | Energy Conservation Measure: A defined improvement, such as air sealing or added insulation, evaluated for installation cost, energy savings, and operational benefit. |
| ECO | Energy Company Obligation: A UK energy-efficiency program requiring obligated energy suppliers to fund qualifying household improvements, including insulation and heating-related measures. |
| ELA | Effective Leakage Area: The calculated area of a single idealized opening that would produce the measured total enclosure leakage at a specified reference pressure. |
| EPA | United States Environmental Protection Agency: The federal regulator overseeing air emissions, chemicals, refrigerants, hazardous materials, indoor environmental issues, and lead-safe renovation requirements. |
| EPC | Energy Performance Certificate: A standardized rating document used in the UK and parts of Europe to communicate a building’s energy performance and recommended improvements. |
| EPD | Environmental Product Declaration: A verified document reporting lifecycle environmental impacts for a product according to defined calculation and disclosure rules. |
| EPDM | Ethylene Propylene Diene Monomer: A durable synthetic rubber widely used for flexible single-ply roofing membranes on low-slope roofs. |
| EPR | Extended Producer Responsibility: A policy approach that assigns producers responsibility for product collection, recycling, or disposal after use, potentially affecting roofing and insulation waste streams. |
| EPS | Expanded Polystyrene: A lightweight rigid-foam insulation made by molding expanded beads, used in roof, wall, foundation, and structural insulated panel applications. |
| ERA | EPDM Roofing Association: A trade association representing manufacturers of synthetic-rubber roof membranes and related materials while publishing technical and sustainability guidance. |
| ESR | Evaluation Service Report: A technical report documenting how a product or system complies with specified building-code provisions, acceptance criteria, and installation conditions. |
| ETA | European Technical Assessment: A documented assessment of an innovative construction product’s performance based on the applicable European Assessment Document. |
| EWI | External Wall Insulation: A retrofit system that places insulation on the exterior of an existing wall and protects it with a compatible finish or cladding system. |
| F | |
| FBC | Florida Building Code: The statewide construction code containing stringent wind, impact, roofing, waterproofing, and product-approval requirements for hurricane-prone conditions. |
| FEMA | Federal Emergency Management Agency: The US agency that publishes resilience and hazard-mitigation guidance for roofs and building enclosures exposed to wind, flood, and severe weather. |
| FM | Factory Mutual Approvals: A testing and certification framework widely used for commercial roof assemblies, including evaluations of wind uplift, fire, hail, and other property-loss risks. |
| FSI | Flame Spread Index: A comparative numerical rating of how rapidly flame travels across a material’s surface under a standardized test. |
| FSK | Foil-Scrim-Kraft: A reinforced facing used on insulation to provide a durable reflective surface and, when properly sealed, vapor-control capability. |
| G | |
| GPS | Graphite Polystyrene: Expanded polystyrene insulation containing graphite particles that reduce radiant heat transfer and improve thermal resistance. |
| GRHC | Green Roofs for Healthy Cities: An industry organization providing training, technical resources, and professional programs for vegetative roofing and green infrastructure. |
| GWP | Global Warming Potential: A measure comparing a greenhouse gas’s heat-trapping effect with carbon dioxide over a specified period, particularly important when selecting foam blowing agents. |
| H | |
| HAM | Heat, Air, and Moisture: A building-physics framework for evaluating the coupled movement of thermal energy, airflow, and moisture through enclosure assemblies. |
| HCFC | Hydrochlorofluorocarbon: A transitional ozone-depleting chemical formerly used in some foam blowing agents and now largely phased out under environmental rules. |
| HDD | Heating Degree Days: A climate metric representing outdoor temperatures below a base temperature, used to estimate heating demand and normalize energy savings. |
| HEP | Home Energy Professional: A US credentialing framework for energy auditors, quality-control inspectors, retrofit installers, and crew leaders working in residential weatherization. |
| HERS | Home Energy Rating System: A standardized methodology for modeling and rating residential energy performance, commonly used for code compliance, certifications, and retrofit analysis. |
| HFC | Hydrofluorocarbon: A class of high-global-warming-potential chemicals formerly common as blowing agents in certain foam insulation products. |
| HFO | Hydrofluoroolefin: A class of low-global-warming-potential chemicals increasingly used as blowing agents in closed-cell foam insulation. |
| HPwES | Home Performance with ENERGY STAR: A US program supporting whole-house assessment and qualified energy-efficiency improvements through participating contractors and sponsors. |
| HUD | United States Department of Housing and Urban Development: The federal department responsible for housing standards and programs that can affect manufactured homes, lead-safe work, rehabilitation, and energy improvements. |
| HVHZ | High-Velocity Hurricane Zone: A Florida code designation for areas subject to extreme hurricane winds, triggering enhanced roof-system testing, attachment, and product-approval requirements. |
| I | |
| IAQ | Indoor Air Quality: The condition of indoor air with respect to pollutants, moisture, ventilation, and occupant health, all of which can be affected by air sealing and insulation work. |
| IBC | International Building Code: A model code governing commercial and multifamily construction, including roof assemblies, foam plastics, fire performance, energy-related interfaces, and weather protection. |
| IBHS | Insurance Institute for Business & Home Safety: A research organization that develops hazard-resilience guidance and the FORTIFIED standards for roofs and buildings exposed to severe weather. |
| ICC | International Code Council: The organization that publishes widely adopted model building, residential, energy, and existing-building codes in the United States. |
| ICC-ES | International Code Council Evaluation Service: An independent service that evaluates construction products and systems for compliance with applicable codes and acceptance criteria. |
| ICF | Insulated Concrete Form: A stay-in-place form system, usually made from rigid foam, that combines concrete structure with continuous thermal insulation. |
| IECC | International Energy Conservation Code: A model energy code establishing requirements for insulation levels, air leakage, roof reflectance in applicable climates, and building-envelope performance. |
| IIBEC | International Institute of Building Enclosure Consultants: A professional association for roofing, waterproofing, and exterior-wall consultants that provides education, technical resources, and credentials. |
| IPMVP | International Performance Measurement and Verification Protocol: A framework for quantifying energy savings by comparing measured or modeled performance before and after efficiency improvements. |
| IRA | Inflation Reduction Act: US legislation that expanded incentives and funding for residential energy efficiency, insulation, air sealing, and related building upgrades. |
| IRC | International Residential Code: A model code covering one- and two-family dwellings, including insulation, air barriers, vapor retarders, roof coverings, ventilation, and weather protection. |
| IRMA | Inverted Roof Membrane Assembly: A protected roof configuration in which insulation is installed above the waterproofing membrane, shielding the membrane from temperature extremes and physical damage. |
| ISO | International Organization for Standardization: A global standards body publishing test, quality, environmental, and performance standards used by construction-product manufacturers and laboratories. |
| IWI | Internal Wall Insulation: An interior-side wall retrofit used where cavity or exterior insulation is impractical, requiring careful management of moisture and thermal bridging. |
| K | |
| KEE | Ketone Ethylene Ester: A high-molecular-weight polymer used to enhance flexibility and chemical resistance in certain thermoplastic roofing membranes. |
| L | |
| LBP | Lead-Based Paint: Regulated paint that may be disturbed during roof, wall, or weatherization work and therefore requires lead-safe procedures in covered buildings. |
| LCA | Life Cycle Assessment: A method for quantifying environmental impacts across a product’s raw-material, manufacturing, transport, use, and end-of-life stages. |
| LCIA | Life Cycle Impact Assessment: The stage of lifecycle analysis that translates inventory data into impact categories such as climate change, resource use, and acidification. |
| LEED | Leadership in Energy and Environmental Design: A green-building rating system whose energy, materials, heat-island, and emissions criteria can influence insulation and roofing specifications. |
| LIHEAP | Low Income Home Energy Assistance Program: A US federal assistance program that helps eligible households manage energy costs and may coordinate with state weatherization services. |
| LSW | Lead-Safe Weatherization: Work practices designed to prevent occupant and worker exposure when energy-efficiency measures disturb painted surfaces that may contain lead. |
| LTTR | Long-Term Thermal Resistance: A standardized estimate of rigid cellular insulation’s thermal resistance after aging, used to represent longer-term performance more accurately than initial values. |
| M | |
| M&V | Measurement and Verification: The process of quantifying actual energy or performance improvements against an established baseline after retrofit measures are installed. |
| MB | Modified Bitumen: Asphalt roofing enhanced with polymers to improve flexibility, durability, and temperature performance in low-slope applications. |
| MC | Moisture Content: The quantity of water held in a material, commonly measured before enclosing roof decks, framing, or insulation to reduce decay and condensation risk. |
| MDI | Methylene Diphenyl Diisocyanate: A reactive chemical used to produce polyurethane products that requires controlled application, ventilation, and appropriate worker protection. |
| MEES | Minimum Energy Efficiency Standards: UK rules establishing minimum energy-performance levels for certain rented properties, helping drive demand for insulation and other efficiency upgrades. |
| MHEA | Manufactured Home Energy Audit: A US energy-audit tool designed to identify cost-effective weatherization measures for manufactured and mobile homes. |
| MRA | Metal Roofing Alliance: A trade organization promoting residential metal roofing and providing market, technical, and installer information. |
| MW | Mineral Wool: A fibrous insulation category made from molten mineral raw materials, valued for thermal, acoustic, and fire-resistant properties. |
| N | |
| NAIMA | North American Insulation Manufacturers Association: A trade association representing manufacturers of fiberglass, mineral wool, and slag wool insulation products. |
| NatHERS | Nationwide House Energy Rating Scheme: Australia’s residential energy-rating framework for assessing thermal performance and supporting code compliance. |
| NBC | National Building Code of Canada: Canada’s model building code, containing requirements for thermal insulation, roofing, moisture control, air leakage, and fire safety. |
| NDL | No Dollar Limit: A commercial roofing warranty structure that does not state a predetermined monetary cap for covered repair obligations, subject to its terms and exclusions. |
| NEAT | National Energy Audit Tool: Audit software used by the US Weatherization Assistance Program to identify and rank cost-effective energy measures for site-built homes. |
| NECB | National Energy Code for Buildings: Canada’s model energy code for larger buildings, establishing requirements for enclosure thermal performance, air leakage, and energy use. |
| NESHAP | National Emission Standards for Hazardous Air Pollutants: US federal standards controlling hazardous air emissions, including asbestos requirements that can affect roof removal and building renovation. |
| NFPA | National Fire Protection Association: A standards organization whose codes and tests address building fire safety, combustible insulation, exterior-wall assemblies, and roofing materials. |
| NFVA | Net Free Ventilating Area: The unobstructed airflow area provided by an attic or roof vent after accounting for screens, louvers, and other restrictions. |
| NIA | National Insulation Association: A North American trade association focused on commercial and industrial insulation systems, workforce development, technical education, and safety. |
| NIOSH | National Institute for Occupational Safety and Health: A US research agency that develops exposure recommendations and worker-protection guidance for chemicals, fibers, dust, and other installation hazards. |
| NLA | Normalized Leakage Area: An airtightness metric that adjusts effective leakage area for building size, enabling comparison among homes or enclosures of different dimensions. |
| NOA | Notice of Acceptance: A Miami-Dade County product approval documenting that a roofing or building-envelope product satisfies specified high-wind and impact requirements. |
| NRC | Noise Reduction Coefficient: A single-number rating of a material’s sound absorption, often used to describe the acoustic contribution of fibrous insulation products. |
| NRCA | National Roofing Contractors Association: A US trade association that publishes roofing manuals, technical bulletins, safety resources, and contractor education. |
| NRCan | Natural Resources Canada: The federal department responsible for Canadian energy-efficiency programs, research, building-energy tools, and consumer energy information. |
| NREL | National Renewable Energy Laboratory: A US national laboratory that develops building-energy research, modeling tools, and analysis relevant to enclosure retrofits and efficiency programs. |
| O | |
| ocSPF | Open-Cell Spray Polyurethane Foam: A low-density, vapor-permeable foam used primarily for interior thermal insulation and air sealing in above-grade assemblies. |
| ODP | Ozone Depletion Potential: A measure of a chemical’s capacity to damage the stratospheric ozone layer relative to a reference compound. |
| Ofgem | Office of Gas and Electricity Markets: Great Britain’s energy regulator, with responsibilities that include administration and oversight of supplier-funded energy-efficiency obligations. |
| ORNL | Oak Ridge National Laboratory: A US national laboratory conducting research on building envelopes, insulation, roofing, moisture, durability, and energy performance. |
| OSB | Oriented Strand Board: An engineered wood panel commonly used for roof and wall sheathing, where moisture condition and fastener capacity affect roof-system performance. |
| OSHA | Occupational Safety and Health Administration: The US regulator responsible for workplace requirements covering fall protection, respiratory protection, chemical exposure, ladders, scaffolds, and hazard communication. |
| P | |
| PAPR | Powered Air-Purifying Respirator: A motor-assisted respirator that draws contaminated air through filters or cartridges and may be required for certain spray-foam or hazardous-material tasks. |
| PAS 2030 | Publicly Available Specification 2030: A UK specification defining requirements for installing energy-efficiency measures in existing dwellings. |
| PAS 2035 | Publicly Available Specification 2035: A UK framework for assessing, designing, coordinating, and evaluating whole-house energy retrofits while managing moisture and performance risks. |
| PCF | Pounds per Cubic Foot: A density unit used to specify and verify insulation, cover-board, and spray-foam material properties. |
| PCR | Post-Consumer Recycled: Describes material recovered after consumer use and incorporated into a new product, an increasingly important specification and environmental-reporting attribute. |
| PCR | Product Category Rule: A set of calculation and reporting instructions that enables consistent environmental declarations for products within the same category. |
| PEL | Permissible Exposure Limit: A legally enforceable occupational exposure threshold for a hazardous substance, typically expressed as an airborne concentration over a defined period. |
| PF | Phenolic Foam: A rigid cellular insulation with low thermal conductivity and favorable fire characteristics, used in selected roof, wall, and building-services applications. |
| PFAS | Per- and Polyfluoroalkyl Substances: A broad class of persistent fluorinated chemicals subject to increasing disclosure and regulatory scrutiny in coatings, membranes, and other construction-product formulations. |
| PFAS | Personal Fall Arrest System: A complete system of anchorage, connector, and body harness designed to stop a worker’s fall, essential for many roofing activities. |
| PIB | Polyisobutylene: A synthetic polymer used in certain flexible single-ply roofing and waterproofing membranes because of its weather and chemical resistance. |
| PIMA | Polyisocyanurate Insulation Manufacturers Association: A North American trade association representing manufacturers of rigid polyisocyanurate insulation and publishing technical and sustainability guidance. |
| PIR | Polyisocyanurate: A thermoset rigid-foam insulation widely used in commercial roofing and wall assemblies because of its high thermal resistance per unit thickness. |
| PMMA | Polymethyl Methacrylate: A fast-curing resin used in reinforced liquid-applied roofing and waterproofing systems, especially at complex transitions and penetrations. |
| PMR | Protected Membrane Roof: A roof assembly that places insulation and protective layers above the waterproofing membrane to reduce thermal cycling and physical damage. |
| PPE | Personal Protective Equipment: Protective clothing and equipment used to control installation hazards, including respirators, eye protection, gloves, hard hats, and fall-protection gear. |
| PSF | Pounds per Square Foot: A pressure or area-load unit used for wind uplift, snow load, ballast, insulation compressive loading, and roof-system design. |
| PSI | Pounds per Square Inch: A pressure or stress unit used to report compressive strength, adhesive performance, and other material properties. |
| PSK | Polypropylene-Scrim-Kraft: A reinforced insulation facing that provides durability, appearance, and varying degrees of vapor control depending on its construction. |
| PUR | Polyurethane: A polymer family used in spray foam, rigid insulation, adhesives, sealants, and protective coatings. |
| PVC | Polyvinyl Chloride: A thermoplastic polymer widely used in heat-welded single-ply roofing membranes because of its durability and chemical resistance. |
| PVDF | Polyvinylidene Fluoride: A fluoropolymer resin used in high-performance coatings for metal roofing, valued for color retention and weather resistance. |
| Q | |
| QCI | Quality Control Inspector: A credentialed professional who independently verifies that federally funded weatherization work complies with approved standards and program requirements. |
| QII | Quality Insulation Installation: A verification protocol, notably used in California energy compliance, confirming that insulation is installed with proper coverage, alignment, and minimal defects. |
| R | |
| RAS | Recycled Asphalt Shingles: Processed roofing-shingle material recovered from manufacturing scrap or tear-offs for use in products such as asphalt paving mixtures. |
| RBS | Radiant Barrier System: A low-emittance surface facing an air space that reduces radiant heat transfer, commonly installed beneath roofs or in attics. |
| RCMA | Roof Coatings Manufacturers Association: A trade association representing manufacturers and suppliers of elastomeric coatings, liquid-applied membranes, cements, and related roof-maintenance products. |
| RdSAP | Reduced Data Standard Assessment Procedure: The UK methodology used to assess the energy performance of existing dwellings when complete construction data are unavailable. |
| REL | Recommended Exposure Limit: A nonregulatory occupational exposure recommendation used to guide controls for fibers, dusts, chemicals, and other workplace hazards. |
| RESNET | Residential Energy Services Network: A US standards and accreditation organization for home energy ratings, energy modeling, and verification of residential efficiency measures. |
| RH | Relative Humidity: The amount of water vapor in air relative to the maximum it can hold at that temperature, central to condensation, drying, and mold-risk analysis. |
| RIMA-I | Reflective Insulation Manufacturers Association International: A trade association representing reflective insulation, radiant barriers, and interior radiation-control coatings. |
| RRP | Renovation, Repair and Painting: The US lead-safety rule requiring certified firms and work practices when covered renovation activities disturb lead-based paint. |
| S | |
| SA | Self-Adhered: Describes membranes or underlayments supplied with factory-applied adhesive for bonding to a prepared substrate without hot asphalt or torch application. |
| SAP | Standard Assessment Procedure: The UK government methodology for calculating and rating the energy performance of new dwellings. |
| SBEM | Simplified Building Energy Model: A UK calculation method used to assess energy performance and demonstrate regulatory compliance for many non-domestic buildings. |
| SBS | Styrene-Butadiene-Styrene: An elastomeric polymer used to modify asphalt, improving low-temperature flexibility and fatigue resistance in roofing membranes and shingles. |
| SDI | Smoke Developed Index: A comparative rating of smoke generated by a material during a standardized surface-burning test. |
| SDS | Safety Data Sheet: A standardized document describing chemical hazards, handling, storage, exposure controls, first aid, and emergency procedures for a product. |
| SEBS | Styrene-Ethylene-Butylene-Styrene: A thermoplastic elastomer used in selected roof coatings, sealants, adhesives, and polymer-modified waterproofing products. |
| SIP | Structural Insulated Panel: A factory-made building panel consisting of an insulating core bonded between structural facings, providing structure and thermal enclosure in one component. |
| SIR | Savings-to-Investment Ratio: The present value of expected energy savings divided by the installed cost of a measure; values meeting program thresholds indicate cost-effectiveness. |
| SLA | Specific Leakage Area: An airtightness metric that divides effective leakage area by a building’s reference area to support comparison across different building sizes. |
| SMP | Silicone-Modified Polyester: A coil-coating resin used on metal roofing that offers a balance of cost, color retention, flexibility, and weatherability. |
| SPF | Spray Polyurethane Foam: A site-applied cellular plastic that expands and cures to provide thermal insulation, air sealing, or a monolithic sprayed roofing layer. |
| SPFA | Spray Polyurethane Foam Alliance: A trade association providing technical guidance, safety resources, training, and installer certification for spray-foam applications. |
| SPRI | Single Ply Roofing Industry: A trade association that develops consensus standards and technical guidance for flexible roofing membranes, insulation, fasteners, edge systems, and related components. |
| SRI | Solar Reflectance Index: A calculated measure combining solar reflectance and thermal emittance to indicate how hot a roof surface is likely to become in sunlight. |
| SRL | Self-Retracting Lifeline: A fall-protection device that extends and retracts with worker movement and locks when sudden acceleration indicates a fall. |
| SSMR | Standing-Seam Metal Roof: A metal roof system with raised, interlocking vertical seams that conceal or minimize exposed fasteners and accommodate controlled thermal movement. |
| STC | Sound Transmission Class: A single-number rating of an assembly’s resistance to airborne sound transmission, often improved through cavity insulation and resilient construction. |
| SVOC | Semi-Volatile Organic Compound: An organic chemical with lower volatility than typical volatile compounds that may still migrate from construction products and affect material-health assessments. |
| T | |
| TAS | Testing Application Standard: A Florida test protocol used to evaluate roof coverings, assemblies, and components for wind uplift, impact, and other high-wind-zone requirements. |
| TE | Thermal Emittance: The ability of a surface to release absorbed heat as infrared radiation, used with solar reflectance to evaluate cool-roof performance. |
| TPO | Thermoplastic Polyolefin: A heat-weldable single-ply roofing membrane commonly used on commercial low-slope roofs. |
| TREAT | Targeted Retrofit Energy Analysis Tool: Building-energy audit software used to model existing performance, compare efficiency measures, and estimate savings and cost-effectiveness. |
| TSCA | Toxic Substances Control Act: The principal US law governing the evaluation and regulation of industrial chemicals, including substances used in or released from construction products. |
| U | |
| UFFI | Urea-Formaldehyde Foam Insulation: A site-foamed cavity insulation used historically in buildings and now primarily encountered during inspection, renovation, or indoor-air-quality assessment. |
| UKCA | UK Conformity Assessed: A product marking used in Great Britain to demonstrate conformity with applicable regulatory requirements for covered goods. |
| UL | Underwriters Laboratories: A safety science and certification organization whose fire, impact, uplift, and material test standards are widely referenced for roofing and insulation products. |
| ULC | Underwriters Laboratories of Canada: A Canadian standards and certification body whose fire and product-performance standards apply to insulation, roofing, and enclosure assemblies. |
| V | |
| VCL | Vapour Control Layer: A material positioned within an assembly to limit water-vapor diffusion and reduce the risk of interstitial condensation. |
| VIP | Vacuum Insulation Panel: A high-performance insulation panel with a porous core enclosed in a gas-tight evacuated envelope, offering very low thermal conductivity but requiring careful handling. |
| VOC | Volatile Organic Compound: An organic chemical that readily enters the air and may be regulated in adhesives, sealants, coatings, foams, and other construction products. |
| VSH | Very Severe Hail: A high-level hail-resistance designation used in property-loss-prevention testing and specifications for roof assemblies in exposed regions. |
| W | |
| WAP | Weatherization Assistance Program: A US federal program funding cost-effective energy improvements and health-and-safety measures for eligible low-income households. |
| WCD | Worst-Case Depressurization: A combustion-safety test that operates exhaust devices and closes interior doors to determine whether building pressure could cause appliance backdrafting or spillage. |
| WFT | Wet Film Thickness: The thickness of a coating immediately after application, measured to help ensure the cured membrane will reach its specified dry thickness. |
| WPN | Weatherization Program Notice: Formal guidance issued by the US Department of Energy to communicate policies, requirements, funding rules, and technical expectations to program grantees. |
| WRB | Water-Resistive Barrier: A drainage-plane material installed behind exterior finishes to prevent liquid water from reaching moisture-sensitive parts of the enclosure. |
| WUFI | Wärme und Feuchte instationär: A family of hygrothermal modeling tools used to simulate transient heat and moisture movement through building assemblies. |
| WVTR | Water Vapor Transmission Rate: The quantity of water vapor passing through a material over a specified area and time under defined test conditions. |
| Wx | Weatherization: A compact industry abbreviation for measures that improve enclosure efficiency, durability, comfort, and safety, especially in program documents and field records. |
| X | |
| XPS | Extruded Polystyrene: A closed-cell rigid-foam insulation with relatively high compressive strength and moisture resistance, used in roofs, walls, foundations, and below-grade assemblies. |